200G QSFP-DD SR8 100m Optical Transceiver

200G QSFP-DD SR8 100m Optical Transceiver

Features:

 

  • Up to 28.05 Gbps data rate per channel by NRZ modulation
  • Support 200GAUI-8 electrical interface
  • Integrated 850nm VCSEL array and PD array
  • Hot-pluggable QSFP-DD form factor
  • Supported MPO-16 APC or 2*MPO-12 UPC
  • Compliant to QSFP-DD HW
  • Compliant with CMIS 4.0
  • Maximum power consumption 3.5W
  • Single 3.3V power supply
  • Case operating temperature 0°C to 70°C
  • Class 1 laser  
  • RoHS compliant
  • Product Detail

200G QSFP-DD SR8  RQD-200GSR8

 

Absolute Maximum Ratings

 

Parameter

Symbol

Min

Max

Unit

Storage Temperature

TS

-40

85

ºC

Power Supply Voltage

VCC

-0.3

3.6 V

Control Input Voltage

VI

-0.3

3.465

V

Relative Humidity (non-condensing)

RH

15 85 %

 

Recommended Operating Conditions

 

Parameter

Symbol

Min.

Typical

Max.

Unit

Notes

Operating Case Temperature

TOPR

    70  

Power Supply Voltage

VCC

3.135

3.3

3.465

V

 

Maximum Power Consumption

Pmax

    3.5 W  

Signaling Rate per Lane

SRL

1.25-

  28.05

Gbps

1

Rx Differential Data Output Load

    100  

Ohm

 

Operating Distance (OM3)

      70 m  

Operating Distance (OM4)

      100 m  

Notes:

1. For Rate <25.78 Gb/s, CDR must be in Bypass mode

 

Transmitter Optical Specifications

 

Parameter

Symbol

Min.

Typical

Max.

Unit

Center Wavelength

λC

840

850 860 nm

RMS spectral width

∆λrms

 

  0.6 nm

Average launch power, each lane

AOPL

-6.4

  3

dBm

Optical Modulation Amplitude (OMAouter), each lane

TOMA

-6.4

  3.5

dBm

Average Launch Power of OFF Transmitter, each lane

ToFF

    -30

dBm

Extinction ratio, each lane

ER

2    

dB

Optical return loss tolerance

      -12

dB

Transmitter Eye mask definition Eye mask definition {X1, X2, X2, Y1, Y2, Y3}

 

{0.3,0.38,0.45,0.35,0.41,0.5}

 

 

Receiver Optical Specifications

 

Parameter

Symbol

Min.

Typical

Max

Unit

Center Wavelength

λC

840   860 nm

Damage threshold

  3.4    

dBm

Average Receive Power, each lane

  -10.3   2.4

dBm

Stressed Receiver sensitivity (OMA)

SOMA

    -5.2

dBm

Receiver reflectance

 

    -12

dB

LOS Assert

LOSA

-30    

dBm

LOS De-Assert

LOSD

    -10.5

dBm

LOS Hysteresis

LOSH

0.5    

dB

 

Pin Definitions

 

200G QSFP-DD SR8 Transceiver

 

Figure 1 –Module Pad Layout

 

Pin

Logic

Symbol

Description

Pin Logic Symbol

Description

1  

GND

Ground

39   GND

Ground

2

CML-I

Tx2n

Transmitter Inverted Data Input

40

CML-I

Tx6n

Transmitter Inverted Data Input

3

CML-I

Tx2p

Transmitter Non-inverted Data Input

41

CML-I

Tx6p

Transmitter Non-inverted Data Input

4  

GND

Ground

42  

GND

Ground

5

CML-I

Tx4n

Transmitter Inverted Data Input

43

CML-I

Tx8n

Transmitter Inverted Data Input

6

CML-I

Tx4p

Transmitter Non-inverted Data Input

44

CML-I

Tx8p

Transmitter Non-inverted Data Input

7  

GND

Ground

45  

GND

Ground

8

LVTTL-I

ModSelL

Module Select

46  

Reserved

 
9

LVTTL-I

ResetL

Module Reset

47

 

VS1

Module Vendor Specific 1

10  

VccRx

+3.3V Power Supply Receiver

48  

VccRx1

3.3V Power Supply

11

LVCMOS-I/O

SCL

2-wire serial interface clock

49  

VS2

Module Vendor Specific 2

12

LVCMOS-I/O

SDA

2-wire serial interface data

50  

VS3

Module Vendor Specific 3

13  

GND

Ground

51  

GND

Ground

14

CML-O

Rx3p

Receiver Non-inverted Data Output

52

CML-O

Rx7p

Receiver Non-inverted Data Output

15

CML-O

Rx3n

Receiver Inverted Data Output

53

CML-O

Rx7n

Receiver Inverted Data Output

16  

GND

Ground

54  

GND

Ground

17

CML-O

Rx1p

Receiver Non-inverted Data Output

55

CML-O

Rx5p

Receiver Non-inverted Data Output

18

CML-O

Rx1n

Receiver Inverted Data Output

56

CML-O

Rx5n

Receiver Inverted Data Output

19  

GND

Ground

57  

GND

Ground

20  

GND

Ground

58  

GND

Ground

21

CML-O

Rx2n

Receiver Inverted Data Output

59

CML-O

Rx6n

Receiver Inverted Data Output

22

CML-O

Rx2p

Receiver Non-inverted Data Output

60

CML-O

Rx6p

Receiver Non-inverted Data Output

23  

GND

Ground

61  

GND

Ground

24

CML-O

Rx4n

Receiver Inverted Data Output

62

CML-O

Rx8n

Receiver Inverted Data Output

25

CML-O

Rx4p

Receiver Non-inverted Data Output

63

CML-O

Rx8p

Receiver Non-inverted Data Output

26  

GND

Ground

64  

GND

Ground

27

LVTTL-O

ModPrsL

Module Present

65  

NC

Not connected

28

LVTTL-O

IntL

Interrupt

66  

Reserved

 

 

Mechanical Dimensions

 

200G QSFP-DD SR8

 

Figure 2 – Mechanical Dimensions for MPO16

 

200G QSFP-DD SR8

Figure 3 – Mechanical Dimensions for 2*MPO12

 

Ordering Information

 

Part Number

Description

RQD-200G-SR8

200Gb/s, QSFP-DD, 2*MPO12, UPC, MMF, 850nm, SR8, up to 100m

RQD-200G-SR8-M16

200Gb/s, QSFP-DD, MPO16, APC, MMF, 850nm, SR8, up to 100m

 

 

Want to know about this product?

SEND A MESSAGE
Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
200G QSFP56 FR4 2KM 200G QSFP56 FR4 2KM LC PAM4 Optical Transceiver
Features 4 duplex channels transmitters and receivers Integrated CWDM LD and PD array LC/UPC connecting interface compliant Single +3.3V power supply DDM function implemented Hot-pluggable QSFP56 form factor Transmission length up to 2km Low power dissipation:
200G QSFP56 SR4 200G QSFP56 SR4 100m 850nm PAM4 Transceiver
Features QSFP56 Serial Optical Interface 4x50G PAM4 retimed 200GAUI-4 C2M electrical interface MPO-12 connector 4 channel VCSEL array and 4 channels PIN photodetector array >Maximum link length of 70m on OM3 or 100m on OM4   QSFP MSA Compliant Hot Pluggable QSFP56 form factor Compliant with SFF8636 Rev 2.10a   Support Protocol Compliant with IEEE 802.3cd   Low Power Consumption Less than 5W in temperature range of 0 to 70℃   Applications 200GBASE-SR4200G Ethernet Data center  
200Gb/s QSFP DD PSM8 10km Optical Transceiver 200Gb/s QSFP DD PSM8 10km Optical Transceiver
The FiberWDM RQD-200G10-PSM8 is a Eight-Channel, Pluggable, Parallel, Fiber-Optic QSFP DD PSM8 for 2×100 Gigabit Ethernet , Infiniband DDR/EDR Applications. This transceiver is a high performance module for data communication and interconnect applications. It integrates eight data lanes in each direction with 208 Gbps bandwidth. Each lane can operate at 26Gbps up to 10km over G.652 SMF. These modules are designed to operate over singlemode fiber systems using a nominal wavelength of 1310nm. The electrical interface uses a 76 contact edge type connector. The optical interface uses an 24 fiber MTP (MPO) connector. This module incorporates FiberWDM proven circuit and Optical technology to provide reliable long life, high performance, and consistent service. 
2-Optical 4-Electric POE Gigabit Industrial Switch FW304GPS-2F 2-Optical 4-Electric POE Gigabit Industrial Switch FW304GPS-2F
4* 10/100/1000Mbps RJ45 ports+2 * Gigabit SFP ports (uplink) FW304GPS-2F is a quasi industrial full gigabit management POE switch, which provides 4 gigabit POE ports, 2 gigabit optical ports, full port supports 6KV lightning protection, power supply over temperature protection, over-voltage protection, surge current protection and other protection features. Support IEEE 802.3x full dual and semi dual backpressure flow control. It conforms to IEEE802.3af&at standard, and the maximum PoE power of a single port is 30W. High reliability protection level, adapt to various complex environments, 48-56V DC redundant dual power supply voltage input, support dual redundant DC power supply or dual DC/AC redundant power supply, and meet the power demand in different power supply environments.
3port 100GHz High Power DWDM 3port 100GHz High Power DWDM C-BAND ITU Component
  Feature Low Insertion loss Wide Pass Band High Channel Isolation High Stability and Reliability Epoxy Free Optical Path  
25G SFP28 Transceiver 25G SFP28 Optical Transceiver
25G SFP28 optical transceiver module, support 25Gb/s and SR up to 100 m transmission, LR 25G SFP28 up to 10 km transmission, and ER 25G SFP28 up to 40 km transmission, it works in high-speed IDC connection solutions, and so on.
100G CFP Module 100G CFP2 LR4 single Rate 10km Module
Features Supports single-rate 103.1Gb/s aggregate(100GE); Lane bit rate 25.78 Gb/s 100GbE; Up to 10km transmission on SMF; LAN WDM laser and PIN receiver; High speed I/O electrical interface (CAUI-4); MDIO interface with integrated Digital Diagnostic monitoring; CFP2 MSA package with duplex LC connector; Single +3.3V power supply; Maximum power consumption 6W; Operating case temperature: -5 to +70 °C; Complies with IEEE802.3bm; Complies with EU Directive 2015/863/EU;   Application 100GBASE-LR4;
10Gb/s 100km CWDM SFP+ Transceiver 10Gb/s 100km CWDM SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 1470~1550nm, CWDM EML&APD, Single mode
Applications:   10GBASE Ethernet Sonet OC-192/SDH 10G Fibre channel CWDM Networks
Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact