200G QSFP56 FR4 2KM LC PAM4 Optical Transceiver

200G QSFP56 FR4 2KM LC PAM4 Optical Transceiver

Features

  • 4 duplex channels transmitters and receivers
  • Integrated CWDM LD and PD array
  • LC/UPC connecting interface compliant
  • Single +3.3V power supply
  • DDM function implemented
  • Hot-pluggable QSFP56 form factor
  • Transmission length up to 2km
  • Low power dissipation:<6.5w
  • International class 1 laser safety certified
  • Operating temperature range: 0℃ ~ +70 ℃
  • Compliant with ROHS10
                                                                                              

Applications

  • 200GBASE-FR4 Ethernet
  • Switch & Router Connections
  • Data Centers
  • Other 200G Interconnect Requirements.

Standards

  • IEEE 802.3cd
  • CMIS Rev 4.0
  • OIF-CEI-04.0 56G-VSR-PAM4
  • IEEE 802.3bs Annex120E
  • SFF-8024 Rev. 4.6
  • SFF-8679 Rev1.8
  • SFF-8665 Rev1.9


  • Product Detail

RQ56-200G-FR4

200G QSFP56 FR4 2KM LC Optical Transceiver

 200G QSFP56

The 200G QSFP56 FR4 Transceiver is designed to transmit and receive optical data links 50 Gb/s bit rate per channel with PAM4 modulation format via up to 2km single mode fiber. It is hot pluggable transceiver with QSFP56 package. The module comprises high performance LD PIN DSP etc.


Specifications

(Tested under recommended operating conditions, unless otherwise noted)

Parameter

Symbol

Unit

Min

Typ

Max

Notes

Transmitter (per Lane)

Signaling Speed per Lane


GBd


26.5625



Modulation format




PAM4





Center wavelength



WL



nm

1264.5

1271

1277.5


1284.5

1291

1297.5


1304.5

1311

1317.5


1324.5

1331

1337.5


Side-mode suppression ratio

SMSR

dB

30




Average Launch Power per Lane

TXPx

dBm

-4.2


4.7


Tx OMA per lane

TXOMA

dBm

-1.2


4.5


Optical Extinction Ratio

ER

dB

3.5




Transmitter and dispersion    eye closure for PAM4 per Lane

TDECQ

dB



3.3


Optical return loss tolerance

ORL

dB



16.5


Relative Intensity Noise

RIN

dB/Hz



-132


Receiver (per lane)

Signaling Speed per Lane




26.5625





Center wavelength



WL



nm

1264.5

1271

1277.5


1284.5

1291

1297.5


1304.5

1311

1317.5


1324.5

1331

1337.5


Damage Threshold

DT

dBm

5.7




Average Launch Power per Lane

RXP

dBm

-8.2


4.7


Receiver reflectance

Rfl

dB



-26


Difference in receive power between any two lanes


dB



4.1


Receiver sensitivity (OMA outer)


dBm



-6


Stressed receiver sensitivity

(OMA outer)


dBm



-3.6



Ordering Information

PN

Package

Data rate

Laser

Detector

Temp

Reach

Others

Application

RQ56-200G-FR4

QSFP56

200G

DFB

PIN

0~70℃

2km

RoHS

200G Base FR4


PN

RQ56-200G-FR4

Description

200G Base FR4 Transceiver -CT

SAP No

-

Customer PN

-


Absolute Maximum Ratings

Parameter

Symbol

Unit

Min

Max

Storage Temperature Range

Ts

-40

+85

Relative Humidity

RH

%

5

85

Power Supply Voltage

Vcc

V

-0.5

+4.0


Recommended Operating Conditions

Parameter

Symbol

Unit

Min

Typ

Max

Operating Case Temperature Range

Tc

oC

0

/

70

Power Supply Voltage

Vcc

V

3.135

3.3

3.465

Baud Rate (Per channel)

BR

GBd


26.5625



Optical Interface

200G QSFP56


Principle diagram

200G QSFP56


Electric Ports Definition

Parameter

Symbol

Unit

Min

Typ

Max

Notes

Supply Voltage

VCC

VCC3.3-Tx

VCC3.3-Rx

V

3.135

3.3

3.465


Power Consumption

Pc

W



6.5


Transceiver Power-on Initialize Time


ms



2000


Transmitter

Differential peak-to-peak input voltage tolerance


mV

900




Differential termination mismatch


%



10


Differential input return loss(SDD11)


dB



See

CEI-56G

-VSR


Common-mode to differential conversion and differential to common-mode

conversion (SCD11,SDC11)


dB



See

CEI-56G

-VSR


Receiver

Differential peak-to-peak output voltage


mV



900


DC Common Mode Voltage

Vcm

mV

-0.35


2.85


AC Common Mode Noise, RMS


mV



17.5


Differential termination mismatch


%



10



Differential output return loss (SDD22)



dB



See

CEI-56G

-VSR


Common-mode to differential conversion and differential to common-mode

conversion (SCD22, SDC22)



dB



See

CEI-56G

-VSR









IIC communication

IIC Clock frequency

-

KHZ

/

400

1000


clock stretching

-

us

/

/

500


Data hold time

-

ns

/

/

/



Package Outline


200G QSFP56



Want to know about this product?

SEND A MESSAGE
Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
200G QSFP56 SR4 200G QSFP56 SR4 100m 850nm PAM4 Transceiver
Features QSFP56 Serial Optical Interface 4x50G PAM4 retimed 200GAUI-4 C2M electrical interface MPO-12 connector 4 channel VCSEL array and 4 channels PIN photodetector array >Maximum link length of 70m on OM3 or 100m on OM4   QSFP MSA Compliant Hot Pluggable QSFP56 form factor Compliant with SFF8636 Rev 2.10a   Support Protocol Compliant with IEEE 802.3cd   Low Power Consumption Less than 5W in temperature range of 0 to 70℃   Applications 200GBASE-SR4200G Ethernet Data center  
200Gb/s QSFP DD PSM8 10km Optical Transceiver 200Gb/s QSFP DD PSM8 10km Optical Transceiver
The FiberWDM RQD-200G10-PSM8 is a Eight-Channel, Pluggable, Parallel, Fiber-Optic QSFP DD PSM8 for 2×100 Gigabit Ethernet , Infiniband DDR/EDR Applications. This transceiver is a high performance module for data communication and interconnect applications. It integrates eight data lanes in each direction with 208 Gbps bandwidth. Each lane can operate at 26Gbps up to 10km over G.652 SMF. These modules are designed to operate over singlemode fiber systems using a nominal wavelength of 1310nm. The electrical interface uses a 76 contact edge type connector. The optical interface uses an 24 fiber MTP (MPO) connector. This module incorporates FiberWDM proven circuit and Optical technology to provide reliable long life, high performance, and consistent service. 
200G QSFP-DD SR8 Transceiver 200G QSFP-DD SR8
Features:   Up to 28.05 Gbps data rate per channel by NRZ modulation Support 200GAUI-8 electrical interface Integrated 850nm VCSEL array and PD array Hot-pluggable QSFP-DD form factor Supported MPO-16 APC or 2*MPO-12 UPC Compliant to QSFP-DD HW Compliant with CMIS 4.0 Maximum power consumption 3.5W Single 3.3V power supply Case operating temperature 0°C to 70°C Class 1 laser   RoHS compliant
Data Center Switch S6750 Data Center Switch 48x10Ge SFP+ ports and 8x100Ge QSFP28 uplink ports S6750-48X8CQB-AC
S6750-48X8CQB-AC 48×1/10GE SFP+ 8×40/100GE QSFP28 2×hot-swapped fans 1+1 power redundancy Models:
DWDM MUX DEMUX 40CH DWDM MUX DEMUX Card
IL<3.5dB , 100GHZ DWDM AAWG Technology Multiplexing of 40 Channels over a Dark Fiber Network Fully Compatible with All ITU-T 1G/10G/25G/40G/100G DWDM Optics Support Metro, Regional and Long Haul DWDM Networks  
Splitter PLC 2X8 SC/APC Plug-in LGX Box Splitter PLC 2X8 SC/APC Plug-in LGX Box 215*150*20MM
Applications   FTTx Systems LAN, WAN and Metro Networks Analog/Digital Passive Optical Networks CATV Networks Other applications in fiber optic systems
MPO TO  LC 4 Channels MPO TO Dual LC Device 2U Rack
48 Cores MPO to 48 LC/UPC 2*24 Cores MPO to 24 LC/UPC 12 Cores MPO to 12 LC/UPC 19 inch 2U Rack
2Channels*200G CFP2 To 2*100G QSFP28 Muxponder Card 2Channels*200G CFP2 To 2*100G QSFP28 Muxponder Card
Product Features: u Supports DWDM transmission and wavelength conversion. u Single board supports 4 channels of 100G bidirectional service access. u Line side supports 2*200G CFP2 DCO coherent optical modules. u Customer side supports various module interface types: 100GBASE-SR4/CWDM4/LR4/PSM4. u Supports ALS (Automatic Laser Shutdown) functionality. u Supports DDM (Digital Diagnostic Monitoring) signal monitoring. u Supports SD-FEC and SC-FEC functionalities. u Compatible with SNMP-based unified network management platform, with management interfaces including CLI (Telnet and console), Web, and NetView (graphical interface).
Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact