Features

  • 4 duplex channels transmitters and receivers
  • Integrated CWDM LD and PD array
  • LC/UPC connecting interface compliant
  • Single +3.3V power supply
  • DDM function implemented
  • Hot-pluggable QSFP56 form factor
  • Transmission length up to 2km
  • Low power dissipation:<6.5w
  • International class 1 laser safety certified
  • Operating temperature range: 0℃ ~ +70 ℃
  • Compliant with ROHS10
                                                                                              

Applications

  • 200GBASE-FR4 Ethernet
  • Switch & Router Connections
  • Data Centers
  • Other 200G Interconnect Requirements.

Standards

  • IEEE 802.3cd
  • CMIS Rev 4.0
  • OIF-CEI-04.0 56G-VSR-PAM4
  • IEEE 802.3bs Annex120E
  • SFF-8024 Rev. 4.6
  • SFF-8679 Rev1.8
  • SFF-8665 Rev1.9


  • Product Detail

RQ56-200G-FR4

200G QSFP56 FR4 2KM LC Optical Transceiver

 200G QSFP56

The 200G QSFP56 FR4 Transceiver is designed to transmit and receive optical data links 50 Gb/s bit rate per channel with PAM4 modulation format via up to 2km single mode fiber. It is hot pluggable transceiver with QSFP56 package. The module comprises high performance LD PIN DSP etc.


Specifications

(Tested under recommended operating conditions, unless otherwise noted)

Parameter

Symbol

Unit

Min

Typ

Max

Notes

Transmitter (per Lane)

Signaling Speed per Lane


GBd


26.5625



Modulation format




PAM4





Center wavelength



WL



nm

1264.5

1271

1277.5


1284.5

1291

1297.5


1304.5

1311

1317.5


1324.5

1331

1337.5


Side-mode suppression ratio

SMSR

dB

30




Average Launch Power per Lane

TXPx

dBm

-4.2


4.7


Tx OMA per lane

TXOMA

dBm

-1.2


4.5


Optical Extinction Ratio

ER

dB

3.5




Transmitter and dispersion    eye closure for PAM4 per Lane

TDECQ

dB



3.3


Optical return loss tolerance

ORL

dB



16.5


Relative Intensity Noise

RIN

dB/Hz



-132


Receiver (per lane)

Signaling Speed per Lane




26.5625





Center wavelength



WL



nm

1264.5

1271

1277.5


1284.5

1291

1297.5


1304.5

1311

1317.5


1324.5

1331

1337.5


Damage Threshold

DT

dBm

5.7




Average Launch Power per Lane

RXP

dBm

-8.2


4.7


Receiver reflectance

Rfl

dB



-26


Difference in receive power between any two lanes


dB



4.1


Receiver sensitivity (OMA outer)


dBm



-6


Stressed receiver sensitivity

(OMA outer)


dBm



-3.6



Ordering Information

PN

Package

Data rate

Laser

Detector

Temp

Reach

Others

Application

RQ56-200G-FR4

QSFP56

200G

DFB

PIN

0~70℃

2km

RoHS

200G Base FR4


PN

RQ56-200G-FR4

Description

200G Base FR4 Transceiver -CT

SAP No

-

Customer PN

-


Absolute Maximum Ratings

Parameter

Symbol

Unit

Min

Max

Storage Temperature Range

Ts

-40

+85

Relative Humidity

RH

%

5

85

Power Supply Voltage

Vcc

V

-0.5

+4.0


Recommended Operating Conditions

Parameter

Symbol

Unit

Min

Typ

Max

Operating Case Temperature Range

Tc

oC

0

/

70

Power Supply Voltage

Vcc

V

3.135

3.3

3.465

Baud Rate (Per channel)

BR

GBd


26.5625



Optical Interface

200G QSFP56


Principle diagram

200G QSFP56


Electric Ports Definition

Parameter

Symbol

Unit

Min

Typ

Max

Notes

Supply Voltage

VCC

VCC3.3-Tx

VCC3.3-Rx

V

3.135

3.3

3.465


Power Consumption

Pc

W



6.5


Transceiver Power-on Initialize Time


ms



2000


Transmitter

Differential peak-to-peak input voltage tolerance


mV

900




Differential termination mismatch


%



10


Differential input return loss(SDD11)


dB



See

CEI-56G

-VSR


Common-mode to differential conversion and differential to common-mode

conversion (SCD11,SDC11)


dB



See

CEI-56G

-VSR


Receiver

Differential peak-to-peak output voltage


mV



900


DC Common Mode Voltage

Vcm

mV

-0.35


2.85


AC Common Mode Noise, RMS


mV



17.5


Differential termination mismatch


%



10



Differential output return loss (SDD22)



dB



See

CEI-56G

-VSR


Common-mode to differential conversion and differential to common-mode

conversion (SCD22, SDC22)



dB



See

CEI-56G

-VSR









IIC communication

IIC Clock frequency

-

KHZ

/

400

1000


clock stretching

-

us

/

/

500


Data hold time

-

ns

/

/

/



Package Outline


200G QSFP56



Want to know about this product?

SEND A MESSAGE
Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
200G QSFP56 SR4 200G QSFP56 SR4 100m 850nm PAM4 Transceiver
Features QSFP56 Serial Optical Interface 4x50G PAM4 retimed 200GAUI-4 C2M electrical interface MPO-12 connector 4 channel VCSEL array and 4 channels PIN photodetector array >Maximum link length of 70m on OM3 or 100m on OM4   QSFP MSA Compliant Hot Pluggable QSFP56 form factor Compliant with SFF8636 Rev 2.10a   Support Protocol Compliant with IEEE 802.3cd   Low Power Consumption Less than 5W in temperature range of 0 to 70℃   Applications 200GBASE-SR4200G Ethernet Data center  
200G QSFP-DD SR8 Transceiver 200G QSFP-DD SR8
Features:   Up to 28.05 Gbps data rate per channel by NRZ modulation Support 200GAUI-8 electrical interface Integrated 850nm VCSEL array and PD array Hot-pluggable QSFP-DD form factor Supported MPO-16 APC or 2*MPO-12 UPC Compliant to QSFP-DD HW Compliant with CMIS 4.0 Maximum power consumption 3.5W Single 3.3V power supply Case operating temperature 0°C to 70°C Class 1 laser   RoHS compliant
China Super C-band 60CH+MON 100GHz DWDM MUX DEMUX 1U Rack LC/UPC Super C-band 60CH+MON 100GHz DWDM MUX DEMUX 1U Rack LC/UPC
Super C-band 60ch+MON 100GHz DWDM MUX/DEMUX 1U LC/UPC This 60 Channels DWDM Mux Demux has 100GHz channel spacing and performs 60 channel multiplexing or demultiplexing at the ITU wavelengths in Super C-band, greatly expanding the effective working spectrum compared with the traditional C band and extended C band. It offers a combination of low optical insertion loss and high channel isolation along with long term reliability Product Information 60 Channels Super C-band 100GHz with Monitor Port, LC/UPC, Dual Fiber DWDM Mux Demux, 1U Rack Mount Configuration Product Application Optical Specifications Parameter Specification Units Notes Min Type Max Channel Spacing 100 Ghz Technology AAWG (Flat-top) Nos of Channel 60 Channels Channel Frequencies ITU Grid THz Available Channel Frequency Range Odd 190.75 196.650 THz 1524.50-1571.65nm Even 190.7 196.600 THz 1524.89-1572.06 Channel Passband -12.5 +12.5 Ghz -0.10 +0.10 nm Center Wavelength Accuracy -0.05 +0.05 nm Insertion Loss@com 6 6.7 dB @Center Wavelength Insertion Loss@mon 22 dB 1% Passband Ripple 1.0 1.5 nm Full Bandwidth Bandwidth @1.0dB 0.22 nm Bandwidth @3.0dB 0.42 nm Bandwidth @20dB 1.20 nm Insertion Loss Uniformity at ITU 1.20 dB Polarization Dependent Loss 0.5 dB Adjacent Channel Isolation 25 dB Non-Adjacent Channel Isolation 30 dB Total Cross Talk 24 24 dB Directivity 40 dB Return Loss with connectors 40 45 dB Chromatic Dispersion -20 +20 ps/nm PDL 0.5 dB PMD 1.0 ps Optical Power Handling of Common Port 24 dBm Net Weight 3.5 KGS Dimensions (HxWxD) 44x481.8x230mm mm Operating Conditions Parameter Min Max Units Temperature -5 65 ℃ Humidity Non-condensing 0 90 % R.H. Storage Conditions Parameter Min Max Units Temperature -40 85 ℃ Humidity Non-condensing 0 90 % R.H.
SFP+ 10G media converter 10G SFP+ Converter
10G Converter is connection between fiber to fiber 10Gbps equipment function as fiber media converter ,or as fiber repeater for long distance transmission.OEO for network backbone(SAN, LAN, MAN). Support SDH/SONET STM-64/OC-192,10G fiber channel,10G Ethernet etc. Can be applied in Telecommunication room, R&D laboratory, Data center, and etc. 1310nm /1550nm/CWDM/DWDM Optical Wavelength Conversion.
Data Center Switch S6750 Data Center Switch 48x10Ge SFP+ ports and 8x100Ge QSFP28 uplink ports S6750-48X8CQB-AC
S6750-48X8CQB-AC 48×1/10GE SFP+ 8×40/100GE QSFP28 2×hot-swapped fans 1+1 power redundancy Models:
50G QSFP28 ER4 50G QSFP+ ER4 40Km 1310nm LC Optical Transceiver
50G QSFP ER4 optical transceiver module, support 50Gb/s and up to 40 km transmission on SM fiber, it works in high-speed IDC connection solutions, 5G network mid-haul solution, and so on.
Single Fiber 1310nm-1610nm CWDM MUX DEMUX Single Fiber 8CH(16 Waves) CWDM MUX DEMUX With Monitor Port
CWDM MUX DEMUX,Multiplexing up to 8 ch for single fiber BIDI transmission 1% Monitor Port for Signal Analyzing or Troubleshooting Passive, Protocol Transparent for Ethernet, FC, OTN, SONET/SDH, etc. Fully Compatible with All ITU-T 1G/10G/25G CWDM Optics Applied to Metro, Regional CWDM Networks  
Network Otaps 8 OTAPs Passive Network Optical Taps Module
8 OTAPs Optical Taps module, Support 4 lines traffic copy Low insertion loss – minimize impact on data flows Fully passive – monitoring infrastructure does not impact network availability Does not modify traffic – tools see real copies of the packets from the network Requires no power and does not have an IP address, providing safety from remote attacks Cost effective – avoid costly expenses managing SPAN ports
Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact